Generell övervakning SIM100


Pasted Graphic

Maretron’s Switch Indicator Module monitors switch closure devices including, but not limited to, safety equipment (e.g., heat, smoke, carbon monoxide, explosive vapor detectors), security systems (e.g., motion, vibration, glass break, door and port hole magnetic switches), and vessel monitoring equipment (e.g., valve closed/open, high water bilge). The SIM100 continually monitors these switch closure devices and broadcasts information over the NMEA 2000® network about the switch state so the crew can be alerted to potential conditions or problems that warrant further investigation.

Advanced features of the SIM100 include the ability to detect whether or not power has been disconnected from the monitored device or if the signal wires have been disconnected due to either corrosion, tampering, or for any other reason (if the monitored device is so equiped). With the SIM100, you can rest assured that critical sensors are receiving power, signal wires are connected, and all the safety, security and vessel functions are under constant supervision.

Features
• Monitors and reports the running statuses of six independently connected devices
• Can detect and report problems like opens and shorts in switch circuits


Products



Part numberDescription
SIM100-01
Switch Indicator Module
SH-449CSTE
Smoke/Heat Detector
BHW100
Bilge High Water Detector
CO-CO1224T
Carbon Monoxide (CO) Detector (Surface Mount White)
VS-07.0HG
Vacuum Switch (7” Hg or 24kPa)
MS-1035
Magnetic Switch Rectangular (Indoor)
MS-1085-N
Magnetic Switch Rectangular (Outdoor)
MS-1055-N
Magnetic Switch Cylinder (Indoor/Outdoor)
MS-1075
Magnetic Switch Recessed (Indoor/Outdoor)
10233
1” FPT Cooling Water Flow Switch
10271
1-1/2” FPT Cooling Water Flow Switch
10231
2” FPT Cooling Water Flow Switch
Specifications



ParameterTypeComment
End of Line Resistor
8 KΩ ± 5%
Included with Maretron-supplied sensors
Certifications


StandardComment
NMEA 2000® Standard
Level A
Maritime Navigation and Radio Communication Equipment & Systems
IEC 61162-3
Maritime Navigation and Radiocommunication Equipment & Systems
IEC 60945
FCC and CE Mark
Electromagnetic Compatibility
NMEA 2000® Parameter Group Numbers (PGNs)




DescriptionPGN #PGN NameDefault Rate
Periodic Data PGNs
127501
Binary Switch Bank Status
1 Time/15 seconds and on switch change
Response to Request PGNs
126464
126996
126998
PGN List (Transmit and Receive)
Product Information
Configuration Information
N/A
Protocol PGNs
059392
059904
060928
065240
126208
ISO Acknowledge
ISO Request
ISO Address Claim
ISO Address Command
NMEA Request/Command/Acknowledge
N/A
Maretron Proprietary PGNs
128720
Configuration
N/A
Electrical



ParameterValueComment
Operating Voltage
9 to 32 Volts
DC Voltage
Power Consumption (Maximum)
100mA
NMEA 2000 Interface
Load Equivalence Number (LEN)
2
NMEA 2000® Spec. (1LEN = 50 mA)
Reverse Battery Protection
Yes
Indefinitely
Load Dump Protection
Yes
Energy Rated per SAE J1113
Mechanical



ParameterValueComment
Size
3.50” x 4.20” x 2.03” (88.9mm x 106.7mm x 51.6mm)
Including Flanges for Mounting
Weight
13 oz. (368.5 g)
 
Environmental


ParameterValue
IEC 60945 Classification
Exposed
Degree of Protection
IP64
Operating Temperature
-25°C to 55°C
Storage Temperature
-40°C to 70°C
Relative Humidity
93%RH @40° per IEC60945-8.2
Vibration
2-13.2Hz @ ±1mm, 13.2-100Hz @ 7m/s2 per IEC 60945-8.7
Rain and Spray
12.5mm Nozzle @ 100liters/min from 3m for 30min per IEC 60945-8.8
Solar Radiation
Ultraviolet B, A, Visible, and Infrared per IEC 60945-8.10
Corrosion (Salt Mist)
4 times 7 days @ 40°C, 95%RH after 2 hour Salt Spray Per IEC 60945-8.12
Electromagnetic Emission
Conducted and Radiated Emission per IEC60945-9
Electromagnetic Immunity
Conducted, Radiated, Supply, and ESD per IEC 60945-10
Safety Precautions
Dangerous Voltage, Electromagnetic Radio Frequency per IEC 60945-12