Maretron’s TLM100 is used to sense fluid levels of tanks by using ultrasonic technology. Ultrasonic, or sound waves, are transmitted via the TLM100 mounted at the top of the tank and the flight times of the sound waves to and from the fluid are measured much like a depth sensor. What this means for you is that there are no difficult to handle long probes protruding into the tank, which often foul and/or corrode. Once the TLM100 calculates and transmits the fluid level over the NMEA 2000® network, you can observe tank levels anywhere on the vessel where there is an NMEA 2000® compatible display such as the Maretron DSM250.

NMEA 2000 TLM 100

The TLM100 is capable of sensing fluid levels in tanks up to 40” (1.02m) in depth. It can be used for diesel, fresh water, waste water, black water, and oil tanks (see TLM150 for gasoline tanks or TLM200 for deeper tanks). Unlike most tank senders that only work with rectangular tanks, the TLM100 can be calibrated for irregular tank shapes so you can know the true fluid level in your tanks.

The TLM100 is mounted directly to the top of tanks using the industry standard SAE J1810 5-hole mounting pattern. The TLM100 can also be mounted to tanks with threaded tank openings using optional adapters that included both a 1.5” NPT and a 1.25” BSP adapter. There are other important TLM100 optional accessories including an airlock for black water applications, which keeps the face of the ultrasonic transmitter from fouling and an optional focus tube to permit use on boats with planing hulls, which is required if the vessel spends a significant amount of time with the bow pitched up.

Most importantly, the TLM100 is NMEA 2000® certified so you can view any and all tank levels anywhere on the vessel when using a compatible NMEA 2000® display. The TLM100 is another key component of Maretron’s N2KView® vessel monitoring and control system.

Products



Part numberDescription
TLM100-01
Tank Level Monitor (40” Depth Tanks)
TA-5H-1.25BSP
1.25” BSP Displacement Hull Tank Adapter
TA-5H-1.5NPT
1.5” NPT Displacement Hull Tank Adapter
TAL-5H
SAE 5-Bolt Pattern Black Water Airlock
TAL-1.25BSP
1.25” BSP Black Water Airlock
TAL-1.5NPT
1.5” NPT Black Water Airlock
TFT-5H
SAE 5-Bolt Pattern Non-Displacement Hull Focus Tube
TFT-1.25BSP
1.25” BSP Non-Displacement Hull Focus Tube
TFT-1.5NPT
1.5” NPT Non-Displacement Hull Focus Tube
Specifications



ParameterValueComment
Accuracy
+/-2%
 
Resolution
+/-1%
 
Number of Tank Types
16
Fuel, Fresh Water, Waste Water, Live well, Oil, etc.
Number of Tanks per Tank Type
16
16 Tanks per Tank Type Numbered 0-15
Maximum Tank Depth
40" (1.02m)
 
Minimum Depth Reading
2” (5.08cm)
Sensor Deadband
Support for Irregularly Shaped Tanks
Yes
Can be Calibrated for any Shape Tank
Programmable Tank Capacity
Yes
Allows Displays to Calculate Amount Remaining
Maximum Tank Angle

15°
Without focus tube
With focus tube
Certifications


StandardComment
NMEA 2000® Standard
Level B
Maritime Navigation and Radiocommunication Equipment & Systems
IEC 60945
FCC and CE Mark
Electromagnetic Compatibility
NMEA 2000® Parameter Group Numbers (PGNs)




DescriptionPGN #PGN NameDefault Rate
Periodic Data PGNs
127505
Fluid Level
0.4 Times/Second
Response to Request PGNs
126464
126996
126998
PGN List (Transmit and Receive)
Product Information
Configuration Information
N/A
Protocol PGNs
059392
059904
060928
065240
126208
ISO Acknowledge
ISO Request
ISO Address Claim
ISO Address Command
NMEA Request/Command/Acknowledge
N/A
Electrical



ParameterValueComment
Operating Voltage
9 to 16 Volts
DC Voltage
Power Consumption (Maximum)
<100mA
Maximum Current Drain
Load Equivalence Number (LEN)
2
NMEA 2000® Spec. (1LEN = 50 mA)
Reverse Battery Protection
Yes
Indefinitely
Load Dump Protection
Yes
Energy Rated per SAE J1113
Mechanical



ParameterValueComment
Size
3.9” x 1.2” x 1.0” (99mm x 30.5mm x 25.4mm)
2.7” dia. X 0.9” (68.6mm dia. x 22.9mm)
8.5” (215.9mm)
Interface Component
Sensor Component
Interconnecting Cable
Weight
12 oz. (340g)
 
Mounting
SAE J1810 5-hole bolt pattern
Can mount to 1.25” BSP or 1.5” NPT using available adapters
Environmental


ParameterValue
IEC 60945 Classification
Exposed
Degree of Protection
IP67
Operating Temperature
-25°C to 55°C
Storage Temperature
-40°C to 70°C
Relative Humidity
93%RH @40° per IEC60945-8.2
Vibration
2-13.2Hz @ ±1mm, 13.2-100Hz @ 7m/s2 per IEC 60945-8.7
Rain and Spray
12.5mm Nozzle @ 100liters/min from 3m for 30min per IEC 60945-8.8
Solar Radiation
Ultraviolet B, A, Visible, and Infrared per IEC 60945-8.10
Corrosion (Salt Mist)
4 times 7 days @ 40°C, 95%RH after 2 hour Salt Spray Per IEC 60945-8.12
Electromagnetic Emission
Conducted and Radiated Emission per IEC60945-9
Electromagnetic Immunity
Conducted, Radiated, Supply, and ESD per IEC 60945-10
Safety Precautions
Dangerous Voltage, Electromagnetic Radio Frequency per IEC 60945-12